Study of the photon radiation performance of electronic personal dosemeters

Texier, C.; Itie, C.; Serviere, H.; Gressier, V.; Bolognese-Milsztajn, T Radiation Protection Dosimetry (2001) v. 96(1-3) p. 245-249 European workshop on individual monitoring of external radiation Helsinki (Finland) 4-6 Sep 2000

Summary

Following the specifications and test methods given by international standards IEC-61526 and ISO 4037, the dosimetry department of the irsn studied the photon radiation performance of seven recent electronic personal dosemeters. The personal dosimetric performance of each piece of equipment was tested with X and gamma radiation between 12 keV and 1.25 MeV.