Enhancing Nuclear Safety


Research

Publications

Uncertainties in doses from intakes of radionuclides assessed from monitoring measurements


Journal title : Radiation Protection Dosimetry
Volume : 121
Issue : 1
Pagination : 40-51
Publication date : 01/12/2006

Document type > *Article de revue

Keywords >

Research Unit > IRSN/DRPH/SDI/LEDI

Authors > BIRCHALL Alan, BLANCHARDON Eric, ETHERINGTON George, MOLOKANOV Andrey, PUNCHER M.

Publication Date > 01/12/2006

Summary

The evaluation of uncertainties in doses from intakes of radionuclides is one of the most difficult problems in internal dosimetry. In this paper, the process of assessing internal doses from monitoring measurements is reviewed and the major sources of uncertainty are discussed. Methods developed independently at HPA and at IRSN for the determination of uncertainties in internal doses assessed from monitoring measurements are described. Both use a Monte Carlo simulation approach. Results are described for three illustrative examples. An alternative method developed at the Los Alamos National Laboratory that uses Bayesian statistical methods is also described briefly.