SharePoint
Aide
Faire avancer la sûreté nucléaire

La Recherchev2

Publications

EPR dosimetry in a mixed neutron and gamma radiation field.


Fermer

Authentification

Email :

Mot de passe :

F. Trompier, P. Fattibene, D. Tikunov1,, A. Bartolotta, A. Carosi and M. C. Doca , Radiation Protection Dosimetry 2004 110 (1-4):437-442.

Type de document > *Article de revue

Mots clés > dosimétrie, EPR, neutrons

Unité de recherche > IRSN/DRPH/SDE/LDRI

Auteurs > TROMPIER François

Date de publication > 01/09/2004

Résumé

Suitability of Electron Paramagnetic Resonance (EPR) spectroscopy for criticality dosimetry was evaluated for tooth enamel, mannose and alanine pellets during the ‘international intercomparison of criticality dosimetry techniques’ at the SILENE reactor held in Valduc in June 2002, France. These three materials were irradiated in neutron and gamma-ray fields of various relative intensities and spectral distributions in order to evaluate their neutron sensitivity. The neutron response was found to be around 10% for tooth enamel, 45% for mannose and between 40 and 90% for alanine pellets according their type. According to the IAEA recommendations on the early estimate of criticality accident absorbed dose, analyzed results show the EPR potentiality and complementarity with regular criticality techniques.