SharePoint
Aide
Faire avancer la sûreté nucléaire

La Recherchev2

Publications

Performance of the electronic personal dosemeter for neutron 'saphydose-n' at different workplaces of nuclear facilities


Fermer

Authentification

Email :

Mot de passe :

Titre de la revue : Radiation Protection Dosimetry Volume : 120 N° : 1-4 Pagination : 383-386 Date de publication : 01/09/2006

Résumé

This paper mainly aims at presenting the measurements and the results obtained with the electronic personal neutron dosemeter Saphydose-N at different facilities. Three campaigns were led in the frame of the European contract EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields'). The first one consisted in the measurements at the IRSN French research laboratory in reference neutron fields generated by a thermal facility (SIGMA), radionuclide ISO sources (241AmBe; 252Cf; 252Cf(D2 O)\Cd) and a realistic spectrum (CANEL/T400). The second one was performed at the Krümmel Nuclear Power Plant (Germany) close to the boiling water reactor and to a spent fuel transport cask. The third one was realised at Mol (Belgium), at the VENUS Research Reactor and at Belgonucléaire, a fuel processing factory