SharePoint
Aide
IRSN, Institut de radioprotection et de sûreté nucléaire

Search our site :

ok

Contact us :

ok
En Fr

Enhancing Nuclear Safety


Research

Publications

Determination of small field output factors and correction factors using a Monte-Carlo method for a 1000 MU/min CyberKnife® system equipped with fixed collimators

​Radiation Measurements / Volume 71, Pages 287-292, December 2014

Document type > *Article de revue

Keywords >

Research Unit > IRSN/PRP-HOM/SDE/LDRI

Authors > MOIGNIER Cyril, HUET Christelle, BARRAUX Victor, BASSINET Céline, BAUMANN Marion, SEBE-MERCIER K.

Publication Date > 20/05/2014

Summary

A new formalism for small field dosimetry has been proposed (Alfonso et al., 2008) with the concept of an additional correction factor k((fclin,fmsr)(Qclin,Qmsr)) which accounts for possible changes in detector response with field size. The aim of this work was to evaluate the response of eight commercially available detectors, then to provide a set of correction factors for a 1000 MU/min CyberKnife® equipped with fixed collimators and to compare them with those obtained for the 800 MU/min CyberKnife® version.


Measurements were performed on a 1000 MU/min CyberKnife® with several active detectors designed for small field dosimetry (two chambers (PTW 31014 and 31018), three high resolution diodes (PTW 60016, 60017 and Sun Nuclear EDGE), a natural diamond (PTW 60003) and two passive dosimeters (Harshaw TLD-7007LiF:Mg,Ti thermoluminescent micro-cube and EBT3 radiochromic films). The CyberKnife® as well as the diode detectors, the PinPoint chamber, the diamond and the LiF micro-cubes were modeled with the PENELOPE Monte Carlo code in order to calculate the output factors in a point-like voxel of water (OFMC,w). A set of k((fclin,fmsr)(Qclin,Qmsr)) correction factors for the active detectors investigated is provided for the 1000 MU/min CyberKnife® in order to be used with the new formalism. A difference up to 2.4%, 2.0 and 1.7% in the correction factor obtained for the two different CyberKnife® models is found for the PTW 60003, the PTW 60016 and the PTW 60017 respectively. Although this difference is small, we recommend using specific with the concept of an additional correction factor k((fclin,fmsr)(Qclin,Qmsr)) correction factors for the 1000 MU/min CyberKnife® when they are available.
Send Print

Full text

Involved IRSN laboratory

Contact


Close

Send to a friend

The information you provide in this page are single use only and will not be saved.
* Required fields

Recipient's email:*  

Sign with your name:* 

Type your email address:*   

Add a message :

Do you want to receive a copy of this email?

Send

Cancel

Close

WP_IMPRIMER_TITLE

WP_IMPRIMER_MESSAGE

Back

Ok